condensation); 5. Download this manual TEMPERATURE CONTROLLER Model: TC10 - Quick Guide . Every group denes all parameters related with a specic function (e.g. can be downloaded (free of charge) from the web-site: The Authorised Representative for this product in the EEA is: Yokogawa Europe BV (Address: Euroweg 2 , 3825 HD Amersfoort, The Netherlands) is the Authorised Representative of. future reference. Looking for more information on our people, technology and solutions? connected to the low-voltage installation. 1 digit @ 25C of room temperature; Electromagnetic compatibility and safety requirements. If this instrument is used in a manner not specified in this manual. period. fail to observe these instructions when operating the product. 2 Cold junction accuracy:0.05C/C after a warm-up of 20 minutes. The UT35A and UT32A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. The Yokogawa TC10-L is an all-in-one, FM approved limit controller with an easy-to-read, 3-color LED display. To change these parameters you need to enter the Conguration mode. switch is a device for turning off the power to the instrument. Input impedance:> 1 M. condensation); 5. Download Manual of YOKOGAWA TC 10-L Controller for Free or View it Online on All-Guides.com. TC10 does not come with a terminal cover. : input type, Control strategy, alarms, etc.). . Can't find your region? V output: 0/2 10 V, galvanically isolated, RL min. Do I need a minus sign ( - ) on the alarm setting value? Model: TC10 - Quick Guide . When the upper display is showing a group and the lower display is blank, this key allows to enter in the selected group. We call this set conguration parameter set (or conguration parameters). The 3-year warranty extends 36 months after shipment from our factory. NOTE: This parameter will be shown only when a linear input has been selected (mV, V or mA). There is minimum vibrations and no impact; 4. Also, YOKOGAWA Electric Corporation assumes no liability for the customer's, failure to comply with these requirements. Model: TC10 Digital Indicating Controller with one universal input, one control output, and one selectable I/O. Also, YOKOGAWA Electric Corporation assumes no liability for the custo-, mer's failure to comply with these requirements. condensation); The ambient temperature is in accordance with the operative temperature (0 to 50C); The relative humidity is in accordance with the instrument specications (20 to 90%); Do not run input wires together with power cables. For SSR, mA and V outputs if the line length is longer than 30 m use a shielded wire. Can I turn off the "C" display with input other than temperature on TC10? 1.Push the button for more than 3 seconds. Push button for more than 3 seconds, the instrument will come back to the standard display. The UT32A-V,-C,-R is an easily configurable single-loop controller for 1/8 DIN sized. The instrument have one complete parameter set. Note: Every change of the dP parameter setting will produce. The TC10-L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user. Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. - Installation of protection and/or safety circuits with respect to a, lightning protector; protective equipment for the system control-, led by the product and the product itself; foolproof or failsafe de-, sign of a process or line using the system controlled by the product, or the product itself; and/or the design and installation of other, protective and safety circuits are to be appropriately implemented, Note: To leave the Configuration session without, - This product is not designed or manufactured to be used in critical, applications that directly affect or threaten human lives. The factory default password for conguration parameters is equal to 30. There is minimum vibrations and no impact; There are no water or other uids (i.e. Product Manual Product Specs Overview Description Documents In Stock CONTROLLER Engineering Manual. Search the full list . OUTLINE DIMENSIONS (mm) 1.1 INSTRUMENT DIMENSIONS 1.2 PANEL CUT-OUT 65 mm min. Category: Controller. Allows to increase the value of the selected parameter. Assign OP4 to the control output operation. (100 to 240 VAC); Insulation voltage: 2300 V rms according to EN 61010-1; Total Accuracy: 0.5% F.S.V. The shallow depth of the controller helps to save instrument panel space. (limit control type) (150 pages), Programmable /indicating controller (96 pages), Digital indicating controller (108 pages), Digital indicating controllers (109 pages), Manual will be automatically added to "My Manuals", Controller YOKOGAWA TC 10-L Engineering Manual, Controller YOKOGAWA UT350 Instruction Manual, Controller YOKOGAWA UTAdvanced UT35A Technical Information, Controller YOKOGAWA Fluidcom S2 User Manual, Controller YOKOGAWA UT35A Operation Manual, Controller YOKOGAWA UT32A-R Operation Manual, Controller YOKOGAWA YS1000 Series User Manual, Controller Yokogawa FA-M3 System Upgrade Manual, Controller YOKOGAWA UT750 Instruction Manual. Select a mounting location having the following characteristics: 2. Copyright 1994-2023 Yokogawa Corporation of America, {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Floating Production Storage & Offloading (FPSO), Special Solutions of OpreX Transformation, Terminal Logistics Suite VP (Terminal Automation), Visual MESA Supply Chain Scheduling (VM-SCS), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Mobile Field Device Management (FieldMate), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), OpreX Data Model Broker / Design Data Validation, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Distributed Fiber Optic Temperature Sensor, Industry and Interface Libraries (Applications and Interfaces), Yokogawa Pre-Engineered Analyzer Solutions - YES, Loading, Metering and Blending Automation, Plant Annunciator and SOE Recording System, Transmitterless SENCOMSMART Sensor Platform, Advanced Control Bioreactor System BR1000, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, TC10-L Temperature Controller Limit Control Type Engineering Manual, TC10-L Temperature Controller Limit Control Type Serial communicaiton protocol, TC10-L Temperature Controller (Limit Control Type), Model TC10-L Temperature Controller (Limit Control Type). be downloaded (free of charge) from the web-site: The Authorised Representative for this product in the EEA is: Viale Indipendenza 56, 27029 Vigevano (PV) - ITALY, The following general safety precautions must be observed during. On the TC10, what does it mean if AL and 1 are lit? The UT55A/UT52A also support open networks such as Ethernet communication. Before connecting the output actuators, we recommend to congure the parameters to suit your application (e.g. a TC J input is programmed). If this instrument is used in a manner not specified in this manual. can be downloaded (free of charge) from the web-site: The Authorised Representative for this product in the EEA is: Yokogawa Europe BV (Address: Euroweg 2 , 3825 HD Amersfoort, The Netherlands) is the Authorised Representative of. 3. Download digitalview ALR-1400 Instructions manual . Can I hide the SP display? IM 05C01E81-01EN, 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, EU Declaration of conformity and Manual retrieval, TC10 is a panel mounting, Class II instrument. 0/4 to 20 mA input wiring for passive transmitter using the auxiliary pws. This manual describes how to use UT55A/UT52A functions other than UT55A/UT52A's communication function and ladder sequence function . the protection provided by this instrument may be impaired. 16 AWG or larger wires rated for at last 75C. The Declaration of Conformity and the manual of the controller can. that no power is being supplied to a cable to be connected. To protect the AL2 and AL3 thresholds against, undesired changes, they are available only at "Parameters, list" level (password: 20). facilities, aviation facilities, and medical equipment. Line resistance: Automatic compensation up to 20W/wire with maximum error 0.1% of the input span. that no power is being supplied to a cable to be connected. Wattmeter power consumption is the estimated hourly, energy consumption (using Load Voltage and Load Current, parameter values), computed on the previous 15 minutes. If this instrument is used in a manner not specified in this manual. IP65 rated as "dust tight" and protected against water projected from a nozzle when the optional panel gasket is mounted (for indoor locations) according to EN 60070-1. There is minimum vibrations and no impact; 4. [3] SSc - Initial scale read-out for linear inputs. Notes: 1. If the other instruments have an SG terminal, how should I wire it? When using an external power supply with 2-wire wiring of TC10, what is the input resistance when inputting 4-20 mA? values and the controller output instantaneous value. "), 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns. View online (36 pages) or download PDF (3 MB) YOKOGAWA TC10 User manual TC10 PDF manual download and more YOKOGAWA online manuals Wattmeter Instantaneous power is continuously computed, as multiplication of the Load Voltage, Load Current parameter. and workmanship for 18 months from the date of manufacturing. user must refer to the Engineering manual for special instructions. US $17.58. Note: The group selection is cyclic as well as the selection of the parameters in a group. Can I use the DI function to switch between auto/manual and between run stop/start? Case: Plastic, self-extinguishing degree: V-0 according to UL 94; Front protection: IP 65 (when the optional panel gasket is mounted) for indoor locations according to EN 60070-1; Terminals protection: IP 20 according to EN 60070-1; Terminal block: 16 screw terminals for cables of. The EU Declaration of Conformity and the manual of the controller. 0 mA = 0 mBar and 20 mA = -1000 mBar (vacuum). switch is a device for turning off the power to the instrument. On burnout, it will be 0 mA. Use a tester or similar device to ensure. of use, service life and misuse are not covered by this warranty. It has been designed, with compliance to the European Directives. [13] AL1 and [30] AL2 will be forced to : for an absolute maximum alarm, them will be forced to the maximum input span, for an absolute minimum alarm, them will be forced to the minimum input span, for all other alarm, them will be forced to zero, [14] HAL1 and [31] HAL2 will be forced equal to the 0.5% of the input span, [35] HYS will be forced equal to 0.05 % of the input span, the CAL group will be reset [51]A.L.P, [52] A.L.O, [53] A.H.P, [54] A.H.O. OUTLINE DIMENSIONS (mm) 1.1 INSTRUMENT DIMENSIONS 1.2 PANEL CUT-OUT 65 mm min. Model TC10 Temperature Controller, Quick Guide, Model TC10 Temperature Controller, Engineering Manual, Model TC10 Temperature Controller, Serial communication protocol Modbus for TC10, New Legislative Framework (NLF) Conforming Products, List of RoHS (2011/65/EU) Directive Compliant Products (6-substances RoHS compliant products), Replacement Guide for TC10 Temperature Controller, The EU Declaration of Conformity TC10 *Log-in Required. rear housing, exposed terminals and wiring on the back. 4 2.4 SERIAL INTERFACE. At the rst start up the instrument will use a default parameter set (factory parameter set); this set is a generic one (e.g. When a TC input is selected and a decimal gure is programmed (see the next parameter) the max. 5.6 FACTORY RESET - DEFAULT PARAMETERS LOADING PROCEDURE. - Wiring should be installed to conform to NEC (National Electrical, Code: ANSI/NFPA-70) or the wiring construction standards in. Wattmeter Instantaneous power is continuously computed, as multiplication of the Load Voltage, Load Current parameter. What is the I/O response time of the TC10? of use, service life and misuse are not covered by this warranty. Configuration Page For: TC10 TEMPERATURE CONTROLLER TC10 TC10; Configuration Page For: TC10 Limit Controller TC10-L TC10-L; 21; Model: LL50A Parameter Setting Tool and PLC Ladder Building Tool - This product is intended to be handled by skilled/trained person-, - This instrument is for Measurement Category No. codes: Cod1 [LMNO] for the Input Type and Control Mode selection and Cod2 [PQRS] for the Alarms and the Service Functions. Related Manuals for YOKOGAWA TC10-L . use only, in an electrical panel which encloses the rear housing. Third edition: Feb. 2018. . The following symbol is, This manual is an essential part of the product; keep it in a safe place for. Current availability for non-stock parts is "Usually ships in 7-10 business days". The UT32A-D is a compact digital indicating controller with selectable 2-loop control. The TC10 is a compact temperature single loop controller with easy -to-read 3 dynamic colors led display. AL on the front of the TC10 is the alarm lamp. 18 months (a year and a half) after shipment from the factory. If applicable, a timer count control monitors the amount of time outside the setpoint and registers the maximum temperature reached. 3. External resistance: 100W max., maximum error 25 V. Cold junction: automatic compensation between 0 to 55C. - Wiring should be installed to conform to NEC (National Electrical, Code: ANSI/NFPA-70) or the wiring construction standards in. The default data are those typical values loaded in the instrument prior to ship it from factory. Does the TC10 come with a terminal cover? Copyright 1994-2023 Yokogawa Electric Corporation, {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Special Solutions of OpreX Transformation, Visual MESA Supply Chain Scheduling (VM-SCS), Visual MESA Production Accounting (VM-PA), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), Digital Plant Operation Intelligence (DPI) Quality Stabilization System, OpreX Data Model Broker / Design Data Validation, OpreX Customer Service Management Software, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Single-Cell Analysis Solution Single Cellome, Distributed Temperature Sensor - Fire Detection/Fire Prevention -, Industry and Interface Libraries (Applications and Interfaces), Advanced Control Bioreactor System BR1000, ALH for FlowCam: Automated Liquid Handling, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, TC10-L Temperature Controller Limit Control Type Engineering Manual, TC10-L Temperature Controller Limit Control Type Serial communicaiton protocol, TC10-L Temperature Controller (Limit Control Type), Model TC10-L Temperature Controller (Limit Control Type), Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), Limit control function (High limit / Low limit), IP65 front panel (when the optional panel gasket is mounted)(optional). 2.It is possible to set a initial scale read-out higher than the full scale read-out in order to obtain a reverse read-out scaling. displayed value becomes 999.9C or 999.9F. TC10-L is a panel mounting, Class II instrument. What is the measured current of the TC10's RTD input? Yes, by changing the DP setting from 0 to 1. Assign OP4 to the control output operation. What settings should I use to output PV transmission from ananalog output terminal on TC10? Can it output the SP setting value? Controller YOKOGAWA . fail to observe these instructions when operating the product. Set detailed parameter out group o1.F (output 1 function) = r.inP. equipment and devices that ensure personnel safety. 2.External components (like zener barriers, etc.) I selected SP value transmission on TC10, but no SP value is displayed. Note: The complete list of the default parameters is available in Appendix A. 1 to 4 indicate the status of outputs 1 to 4. On the TC10, what does it mean if AL and 1 are lit? All information. TC10. ), Panel cutout: 45[-0, +0.6] x 45[-0, +0.6] mm (1.78[- 0.000, +0.023] x 1.78[- 0.000, +0.023] in.). TC10 4; TC10-L 4; TDLS200 3; TDLS220 2; TIO0110; TM20; TX10 3; TY500; TY700 2; U. UD350; UM330 4; UM331 2; UM33A 3; UP350 3; UP35A 3; UP550 7; . Note: For TC wiring use proper compensating cable preferable shielded. When the instrument is powered, it starts immediately to work according to the parameters values loaded in its memory. When you do this, the upper limit range of 1000C becomes 999.9C. ]inP Group - Main and auxiliary input conguration. connected to the low-voltage installation. Can I output in the 100% direction (20 mA or more) upon burnout? SKU:WE4537266 SSc allows the scaling of the analog input to set the minimum displayed/measured value. The ambient temperature is in accordance with the operative, 6. The relative humidity is in accordance with the instrument, The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - Digital Input (DI2) connecting a free of. Moreover, provide indication that the. With thermocouple K input, can I display digits after the decimal point for the temperature? The UT32A-D is a compact digital indicating controller with selectable 2-loop control. All information about the controller use can be found in the Engineering Manual: IM 05C01E81-12EN and the Communication Manual: IM 05C01E81-13EN and General Specification: GS 05C01E81-11EN. A reinforced isolation must be assured by the external solid state relays. The SP value is not displayed if you dont specify a control operation. The shallow depth of the controller helps to save instrument panel space. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. The following symbol is, This manual is an essential part of the product; keep it in a safe place for. D + D - D + D - D + D - D + D - RS-485 5 6 Current availability for non-stock parts is "Usually ships in 7-10 business days". For measurements performed in the building instal-, For measurements performed at the source of the, - Wiring work must be carried out by a person with basic electrical, - Be sure to turn OFF the power supply to the controller before wiring, to avoid an electric shock. OUTLINE DIMENSIONS (mm) 1.1 INSTRUMENT DIMENSIONS 48 PV Optional gasket 1.2 PANEL CUT-OUT 45 +0.6 mm 1.78 +0.023 There is minimum vibrations and no impact; 4. {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Floating Production Storage & Offloading (FPSO), Special Solutions of OpreX Transformation, Terminal Logistics Suite VP (Terminal Automation), Visual MESA Supply Chain Scheduling (VM-SCS), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Mobile Field Device Management (FieldMate), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), OpreX Data Model Broker / Design Data Validation, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Distributed Fiber Optic Temperature Sensor, Industry and Interface Libraries (Applications and Interfaces), Yokogawa Pre-Engineered Analyzer Solutions - YES, Loading, Metering and Blending Automation, Plant Annunciator and SOE Recording System, Transmitterless SENCOMSMART Sensor Platform, Advanced Control Bioreactor System BR1000, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, Support Information - New Legislative Framework (NLF) Conforming Products, Temperature Control for Seal-heating Parts in Wrapping Machinery. - Install the power cable keeping a distance of more than 1 cm from, - The power cable is required to meet the IEC standards concerned or the. Use a tester or similar device to ensure. At this point you can set the operator. On the TC10, I want the difference lower limit alarm to be ON 5C below the setpoint value. The readout is updated every 15 minutes. At power ON the instrument can operate in two different mode according to the value assigned to [34] r.md parameter [34] r.md equal to 0, (Limit output is de-energized at power on in any cases.). It also includes a ladder sequence function. When the maximum front protection (IP65) is. Yokogawa TC10-L Temperature Controller Datasheet PDF, Yokogawa TC10-L Limit Controller Quick Reference Guide, Yokogawa TC10-L Temperature Controller Manual PDF, Yokogawa TC10-L Temperature Controller Brochure PDF, Yokogawa UT150L to TC10-L Cross Reference Guide PDF, Universal Input: (TC, mV, V, mA, Pt100-Pt1000), Limit control function (High limit / Low limit), Includes one digital input for external limit reset. Moreover, provide indication that the. WARNING! YOKOGAWA TC10-L: Quick Manual| Brand: Want to have your manuals available on hand: always and everywhere? What is the input resolution specification the TC10? The output relay is always de-energized (opened) at poweron,even if PV does not exceed SP(A). The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. The TC10L features universal - input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the Controller YOKOGAWA TC 10-L Engineering Manual, Controller YOKOGAWA UT350 Instruction Manual, Controller YOKOGAWA FX103 User Manual, Controller YOKOGAWA UT32A User Manual, Controller YOKOGAWA UTAdvanced UT35A Technical Information. The TC10 communication setting criteria are as follows. I want to use it as a display. Case: Plastic, self-extinguishing degree: V-0 according to UL 94, Front protection: IP 65 (when the optional panel gasket is mounted) for indoor locations according to EN 60070-1, Terminals protection: IP 20 according to EN 60070-1, Terminal block: 16 screw terminals for cables of 0.25 to 2.5 mm2 (AWG22 to AWG14) with connection diagram, tightening torque 0.5 Nm, Dimensions: 48 x 48, depth 62 mm (1.89 x 1.89 x 2.87 in. For measurements performed in the building instal-, For measurements performed at the source of the, - Wiring work must be carried out by a person with basic electrical, - Be sure to turn OFF the power supply to the controller before wiring, to avoid an electric shock. The TC series of temperature controllers is perfect for controlling the heating temperature of sealing parts and the temperature of sealing rolls (pre-heating) in a variety of different wrapping machinery. The Yokogawa TC10 is a compact,all-in-one, single loop temperature controller with an easy-to-read, 3-color LED display. The TC10 supports easy configuration with codes for quick start-up. TC10 is a panel mounting, Class II instrument. It has been de-, signed with compliance to the European Directives. countries or regions where wiring will be installed. Note: For TC wiring use proper compensating cable preferable shielded. If the other instruments have an SG terminal, how should I wire it? IP65 Certification when the optional panel gasket is mounted. View online (2 pages) or download PDF (1 MB) YOKOGAWA TC10 User manual TC10 measuring, testing & control PDF manual download and more YOKOGAWA online manuals and access the next parameter within the same group. Before connecting the output actuators, we recommend to congure the parameters to, Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. terminal 1 and 2 to transmitter signal output. . - For control relay output, alarm relay output, and power terminal, -N o C o o o D o F Temperature Controller, The TC10-N can be easily configured by the "Code Configuration" method for the most common requirements, just entering two 4-digit. Id like to confirm the parameters that can be set for TC10 RS485 communication setting criteria (protocol, baud rate, parity, stop bit, data length). I'm looking for a replacement for the UD310. that no power is being supplied to a cable to be connected. 1. Yokogawa Electric Corporation - TC10 - ENGINEERING MANUAL - PAG. the controller use can be found in the Engineering Manual: IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN. 1.Do not run input wires together with power cables. - Installation of protection and/or safety circuits with respect to a, lightning protector; protective equipment for the system controlled, by the product and the product itself; foolproof or failsafe design, of a process or line using the system controlled by the product or, the product itself; and/or the design and installation of other, protective and safety circuits are to be appropriately implemented, Note: To leave the Configuration session without, - This product is not designed or manufactured to be used in critical, applications that directly affect or threaten human lives. The TC10-L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user. A long press allows you to close the conguration parameter procedure (the instrument will come back to the standard display). TC10 is a panel mounting, Class II instrument. This instrument is intended for permanent installation, for indoor use only, in an electrical panel which encloses the rear housing, exposed terminals and wiring on the back. Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), Easy User Control for high limit or low limit, Timer (Counts the total time the setpoint is exceeded), Register to retain the maximum temperature reached, Serial communication: RS-485 Modbus (optional), IP65 front panel (when the optional panel gasket is mounted)(optional), Universal Input: TC, mV, V, mA, Pt100, Pt1000, Power consumption: 6.0 VA max. With the /GK suffix, the TC10 supports the IP65. 0.25 to 2.5 mm2 (AWG22 to AWG14) with connection diagram, tightening torque 0.5 Nm; Dimensions: 48 x 48, depth 73 mm, (1.89 x 1.89 x 2.87 in. Model TC10 Temperature Controller, Quick Guide, Model TC10 Temperature Controller, Engineering Manual, Model TC10 Temperature Controller, Serial communication protocol Modbus for TC10, New Legislative Framework (NLF) Conforming Products, List of RoHS (2011/65/EU) Directive Compliant Products (6-substances RoHS compliant products), Replacement Guide for TC10 Temperature Controller, The EU Declaration of Conformity TC10 *Log-in Required, Temperature Controllers 2D CAD *Log-in Required, Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), IP65 front panel (when the optional panel gasket is mounted)(optional).